Unmanaged 10BASE-T1L Ethernet-APL Interoperable PSE Switch

OmniConverter® GLAPS/Sx

OmniConverter GLAPS RJ-45 Terminal ClassC
OmniConverter GLAPS/Sx Unmanaged, 2xRJ 45 (10/100/1G) Up link + 4 x 10BASE-T1L APS Terminal Connector Ports, 1.0V, Class C,Direct DC input, +24 to + 48VDC, Extended Temp -40° to 75°C


Part Number

2955-1-40-9Z

icons
Add to Quote

  • Description
  • Specifications
  • Documents
OmniConverter GLAPS/Sx Unmanaged, 2xRJ 45 (10/100/1G) Up link + 4 x 10BASE-T1L APS Terminal Connector Ports, 1.0V, Class C,Direct DC input, +24 to + 48VDC, Extended Temp -40° to 75°C

Specifications

Description

OmniConverter® GLAPS/Sx

10T/T1L to 100/1000 Fiber or 10/100/1000 Copper Uplinks
Unmanaged 10BASE-T1L PSE Ethernet Switch

Base Model Number 2052 2937 2953 2939 2941 2943
Standard Compliances

IEEE 802.3,

10BASE-T1L compliant

Regulatory Compliances (Pending)

Safety: UL 62368-1, UL 60950-1,

             IEC 62368-1, IEC 60950-1,

             CUL CSA C22.2 No. 60950,

             EN 60950-1:2006

             CE Mark,

             UKCA

EMI:      FCC 47CFR, Part 15 Class A

             AS/NZS 3548, AS/NZS 4417.1 and AS/NZS 4417.2

             ICES-003 Issue 3

             EN 55032/CISPR 22 and EN55035

             EN61000-3-2

             VCCI V3/2001.04 (CISPR 22A:1997, Class A)

EMC:    IEC/EN61000-4-2, IEC/EN61000-4-3

             IEC/EN61000-4-4, IEC/EN61000-4-5

             IEC/EN61000-4-6, IEC/EN61000-4-8

             IEC/EN61000-4-11

ACT:     TAA, BAA, NDAA

Environmental REACH, RoHS and WEEE
Frame Size Up to 2,048 bytes
Port Types

10BASE-T1L:

3-Pin Terminal or
IEC 63171 Connector


Model 2952 Class A
edge/field device:
24 to 48 VDC
1.0 V peak-to-peak; 0.5 W


Model 2937 Class A
edge/field device:
12 to 15 VDC
1.0 V peak-to-peak; 0.5 W

3-Pin Terminal or
IEC 63171 Connector


Model 2952 Class A
edge/field device:
24 to 48 VDC
1.0 V peak-to-peak; 0.5 W


Model 2937 Class A
edge/field device:
12 to 15 VDC
1.0 V peak-to-peak; 0.5 W

3-Pin Terminal or
IEC 63171 Connector


Class 3
edge/field device:


46 to 50 VDC
2.4 V peak-to-peak,
36 W

3-Pin Terminal or
IEC 63171 Connector


Class 4
edge/field device:


46 to 50 VDC
2.4 V peak-to-peak,
92 W

Uplink:

RJ-45: 10/100/1000BASE-T

SFP: 100BASE-X and 1000BASE-X Fiber Transceivers, 1000BASE-T Copper Transceivers

10/100/1000BASE-T SGMII Copper Transceivers

Cable Types

10BASE-T1L:

 

 

  RJ-45 Copper:

 

Fiber:

Single-Pair Ethernet (SPE) cable,

IEC 61156-13 (fixed) or IEC 61156-14 (flexible) 18AWG cable or better

 

EIA/TIA 568A/B, Cat 3 UTP and higher

 

Multimode: 50/125, 62.5/125μm

Single-mode: 9/125μm

DC Power Requirements

(with DC Terminals)

+24 to +48VDC;
0.36A @ 48VDC
2 Pin Terminal

+12 to +15VDC;
0.78A @ 12VDC
2 Pin Terminal

+24 to +48VDC;
0.52A @ 48VDC
2 Pin Terminal

+12 to +15VDC;
0.94A @ 12VDC
2 Pin Terminal

+46 to +50VDC;
5.16A @ 48VDC
2 Pin Terminal

+46 to +50VDC;
8.20A @ 48VDC
2 Pin Terminal

Dimensions

(W x D x H)

6.28” x 5.2” x 1.5” (159.5 mm x 132.1 mm x 38.1 mm)

Weight

1.5 lb.; 720 grams

Operating Temperature

Commercial: 0 to 50°C

Wide: -40 to 60°C (-20°C AC cold start)

Extended: -40 to 75°C (-20°C AC cold start)

Storage: -40 to 80°C

Humidity 5 to 95% (non-condensing)
Altitude -100m to 4,000m (operational)
MTBF (hours)

224,000

224,000

224,000

224,000

220,000

220,000

Warranty 5 year warranty with 24/7/365 free Technical Support

 

Hazardous Area Use Disclaimer:
This product is not certified for use in hazardous (classified) locations, including Zone 0, Zone 1, or Zone 2 as defined by IEC 60079-10-1 or equivalent national standards.
It is intended for installation in non-hazardous (safe) areas only.
The product supports interoperability with Ethernet-APL networks and devices, including those installed in hazardous zones, provided that all connections are made through
certified intrinsically safe interfaces as part of a compliant system architecture.
When connecting to devices located in hazardous areas, appropriate energy-limiting devices, field switches, or barriers must be used to ensure compliance with all applicable
safety standards.