The iConverter 2-Module Power Chassis is a compact, versatile chassis featuring a single internal universal AC or 18-60VDC power supply. The chassis provides housing for all iConverter media converters and switch modules.
The 2-Module Chassis features a backplane that enables sharing of Ethernet data between two installed iConverter modules that are equipped with Ethernet backplane ports. This enables the chassis to support a variety of networking configurations. Installing an iConverter copper-to-fiber module and a four-port switch module provides a fiber uplink and five 10/100 user ports. A fiber-to-fiber module can be used to provide an access point in a fiber ring, supporting four 10/100 user ports.
In Enterprise networks, the 2-Module Chassis can be used to extend a fiber network connection across a campus or to add a node to an existing fiber ring. The 2-Module Chassis provides a carrier-grade solution; combining media conversion with a managed, compact edge switch.
In Service Provider networks, installing an iConverter Network Interface Device (NID) plug-in module and a four-port switch module provides a securely managed Carrier Ethernet demarcation for one or more User-to-Network Interfaces (UNI). This configuration provides an MEF certified deployment supporting advanced Operation, Administration and Maintenance (OAM) features.
Equipped with an iConverter management module or a module with integrated management, the 2-Module Chassis provides a securely managed solution capable of supporting advanced Ethernet services for Enterprise and Service Provider metro networks. It can be remotely managed via IP-based SNMP or Telnet.
Modules with integrated management, such as the iConverter 10/100M2, installed in the 2-Module Chassis can also provide remote management for the configuration and monitoring of the installed modules. This provides a flexible solution for Enterprise or Service Provider applications where a securely managed edge device is required.
The 2-Module Chassis can be wall-mounted using the optional wall mounting kit or installed on a stable, flat surface.
Management is accomplished by using an optional iConverter Network Management Module (NMM) or an iConverter module with integrated management, such as the 10/100M2. Management can be accessed through a menu-driven command-line interface (CLI) via Telnet or the Serial Console Port. Management can also be accessed through a SNMPbased graphical user interface (GUI) such as Omnitron's NetOutlook management software.
The intuitive NetOutlook network management software provides real-time detailed port and module information as well as parameter configuration and event monitoring. NetOutlook can be used as a stand-alone application under Windows 98/XP/NT/2k/Vista or integrated with third-party SNMP management software.
Fixed parameters that can be monitored include chassis configuration, power supply health status and network traffic statistics for the modules.
In addition to all standard iConverter SNMP traps such as module insertion and removal, 2-Module Chassis models 8230-1, 8231-1, 8235-1 and 8236-1 support Dying Gasp traps (Power Loss Traps) in the event of loss of power. All of these events can be selectively enabled or disabled to cause SNMP traps.
In this Enterprise application, media converter modules are installed in a managed iConverter 19-Module Chassis for highdensity fiber distribution from UTP switch equipment. A fiber ring connects both buildings to the Network Core. At each building, a fiber-to-fiber module is installed in a 2-Module chassis with a four-port switch module. The two modules share data via the Ethernet Backplane. This configuration functions as a remotely managed departmental switch with a fiber ring to the Network Core and four 10/100 ports. The 2-Module chassis can also be utilized in a point-to-point application as illustrated in the Service Provider application.

In this Service Provider application, media converter modules are installed in a managed iConverter 19-Module Chassis for high-density fiber distribution from UTP switch equipment. At the Customer Premises, an iConverter NID module and a fourport switch module are installed in a 2-Module Chassis. A fiber link between the Central Office and the Customer Premise provides a securely managed demarcation solution supporting advanced OAM fault detection and performance monitoring.

| Chassis Type | 2-Module AC 8.5 watts | 2-Module AC 16.5 watts | 2-Module DC 6.6 watts |
2-Module DC 16.5 watts |
| Model Number Standard Dying Gasp | 8230-0 8230-1 |
8231-0 8231-1 |
8235-0 8235-1 |
8236-0 8236-1 |
| Module Capacity | 2 | |||
| Power Supply Capacity | Fixed Internal | |||
| Input Power Requirements (typical) | 100 to 240VAC, 50/60Hz 0.5A @ 120VAC |
100 to 240VAC, 50/60Hz 0.5A @ 120VAC |
+/- 18 to 60VDC -48VDC @ 1.0A |
+/- 18 to 60VDC -48VDC @ 2.0A |
| Backplane Power | 2.6A @ 3.3VDC 1.5A per slot | 5A @ 3.3VDC 2.5A per slot | 2A @ 3.3VDC 1.5A per slot | 5A @ 3.3VDC 2.5A per slot |
| Dimensions | W:6.7" x D:5.51" x H:1.87" | |||
| Weight | 2.5 lbs | |||
| Compliance | UL, CE, FCC Class A, NEBS Level 3 | |||
| Temperature | Standard: 0 to 50º C Wide: -40 to 60º C Storage: -40 to 80º C |
|||
| Humidity | 5 to 95% (non-condensing) | |||
| Altitude | -100m to 4000m | |||
| MTBF (hrs) | 151,000 | 413,000 | 329,000 | 538,000 |
| Configuration | 2-Module AC 8.5 watts | 2-Module AC 16.5 watts | 2-Module DC 6.6 watts | 2-Module DC 16.5 watts |
| 2-Module Chassis | 8230-0 | 8231-0 | 8235-0 | 8236-0 |
| 2-Module Chassis with Dying Gasp Support |
8230-1 | 8231-1 | 8235-1 | 8236-1 |
| Wall-Mount Hardware Kit | 8249-0 | 8249-0 | 8249-0 | 8249-0 |
| Blank Module Panel | 8090-0 | 8090-0 | 8090-0 | 8090-0 |
For wide temperature (-40 to 60º C), add a "W" to the end of the model number. |
||||